-40%
New ABB 3-Pole 3NO IEC Non-Reversing Contactors Max 50A 600VAC AF38ZB-30-00RT-22
$ 52.77
- Description
- Size Guide
Description
4200SA8B.85New ABB 3-Pole / 3 Contacts Normally Open, IEC AC-1, AC-3 Rated Non-Reversing Motor Contactors, Coil Voltage: 48~130 VAC/VDC, General Use Rating Maximum 50A 600VAC, Part Number AF38ZB-30-00RT-22 or AF38ZB3000RT22, Product ID 1SBL296060R2200. Each bid quantity is for One (1) Contactor. You may bid / buy any number, up to the total quantity available above.
These were purchased at an unclaimed freight liquidation earlier this year, and they are brand new in the original factory boxes.
According to the manufacturer
:
General Information
Extended Product Type:AF38ZB-30-00RT-22
Product ID:1SBL296060R2200
EAN:3471523129122
Catalog Description:AF38ZB-30-00RT-22 48-130V50/60HZ-DC Contactor
Long Description: AF38ZB..RT 3-pole contactors comply with the latest railway rolling stock standards and allow installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. Improve the compactness of the installations thanks to reduced dimension and side-by-side mounting requiring less 15% width (without spacing) from -40 °C up to +70 °C. Meet all main rollling stocks standards: IEC 60947-4-1, IEC 60947-5-1, IEC 60077-1/-2 and applicable parts of EN 50155 standards, shocks and vibration withstand conforming to IEC 61373 cat. 1, class B. Reach the highest levels in fire and smoke behaviour with compliance to European standard EN 45545-2 (HL2, HL3 hazard levels) in group mounting Reduce train energy with lighter devices and requiring 68% less coil energy consumption in operation. Electronic coil interface handling large DC voltage fluctuation voltage, including several Uc DC control voltages used for battery supply and accepting sinusoïdal AC 50/60 Hz control supplies included inside Ucmin.... Ucmax voltage range. Max permitted AC 50/60 Hz control voltage must not be exceeded (see technical data). Wide range of auxiliary contact blocks for front and side mounting.
Categories: Products » Low Voltage Products and Systems » Control Products » Contactors » Across the Line Contactors
Classifications
Object Classification Code:Q
ETIM 4:EC000066 - Magnet contactor, AC-switching
ETIM 5:EC000066 - Magnet contactor, AC-switching
ETIM 6:EC000066 - Power contactor, AC switching
ETIM 7:EC000066 - Power contactor, AC switching
UNSPSC:39121529
Certificates and Declarations (Document Number)
CB Certificate:CB_SE-96552
CCC Certificate:CCC_2010010304445623
Declaration of Conformity - CE:1SBD250004U1000
EAC Certificate:EAC_RU C-FR ME77 B03597
Environmental Information:1SBD250165E1000
Instructions and Manuals:1SBC101035M6801
RoHS Information:1SBD250004U1000
UL Certificate:UL_20121122-E312527_9_5
UL Listing Card:UL_E312527
Technical UL/CSA General Use Rating UL/CSA:(600 V AC) 50 A
Horsepower Rating UL/CSA:(220 ... 240 V AC) Three Phase 10 hp
(440 ... 480 V AC) Three Phase 20 hp
(550 ... 600 V AC) Three Phase 25 hp
(120 V AC) Single Phase 2 hp
(200 ... 208 V AC) Three Phase 10 hp
(240 V AC) Single Phase 5 hp
Environmental
Ambient Air Temperature:Close to Contactor for Storage -60 ... +80 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C
Climatic Withstand:Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:3000 m
RoHS Status:Following EU Directive 2011/65/EU
Technical
Number of Main Contacts NO:3
Number of Main Contacts NC:0
Number of Auxiliary Contacts NO:0
Number of Auxiliary Contacts NC:0
Rated Operational Voltage:Main Circuit 690 V
Rated Frequency (f):Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 50 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 50 A
(690 V) 60 °C 42 A
(690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie):
(220 / 230 / 240 V) 60 °C 40 A
(380 / 400 V) 60 °C 38 A
(415 V) 60 °C 38 A
(440 V) 60 °C 38 A
(500 V) 60 °C 33 A
(690 V) 60 °C 24 A
Rated Operational Power AC-3 (Pe):
(220 / 230 / 240 V) 11 kW
(380 / 400 V) 18.5 kW
(415 V) 18.5 kW
(440 V) 22 kW
(500 V) 22 kW
(690 V) 22 kW
Rated Short-time Withstand Current (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
for 1 s -empty- A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
Maximum Electrical Switching Frequency:
AC-1 600 cycles per hour
AC-2 / AC-4 150 cycles per hour
AC-3 1200 cycles per hour
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp):6 kV
Maximum Mechanical Switching Frequency:3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 48 ... 130 V
60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
Operate Time:Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Terminal Type:Ring-Tongue Terminals
Dimensions
Product Net Width:45 mm
Product Net Depth / Length:86 mm
Product Net Height:86 mm
Product Net Weight:0.36 kg
Popular Downloads
Instructions and Manuals:1SBC101035M6801
Customs Tariff Number:85364900