-40%
LC1F400F7 SCHNEIDER Contactor 3 poles AC3 400A 110Vca ALSO available 220Vac
$ 660
- Description
- Size Guide
Description
TeSys F Contactors-
LC1F400F7
Also available in 220Vac
LC1F400M7(Just let us know which coil you need)
Main
range
TeSys
product name
TeSys F
product or component type
Contactor
device short name
LC1F
contactor application
Motor control
Resistive load
utilisation category
AC-1
AC-3
AC-4
poles description
3P
power pole contact composition
3 NO
System Voltage
<= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current
500 A (<= 104 °F (40 °C)) at <= 440 V AC AC-1
400 A (<= 131 °F (55 °C)) at <= 440 V AC AC-3
motor power kW
75 kW at 400 V AC 50/60 Hz AC-4
200 kW at 380...400 V AC 50/60 Hz AC-3
220 kW at 415 V AC 50/60 Hz AC-3
250 kW at 440 V AC 50/60 Hz AC-3
257 kW at 500 V AC 50/60 Hz AC-3
185 kW at 1000 V AC 50/60 Hz AC-3
110 kW at 220...230 V AC 50/60 Hz AC-3
280 kW at 660...690 V AC 50/60 Hz AC-3
[Uc] control circuit voltage
110 V AC 40...400 Hz
Complementary
[Uimp] rated impulse withstand voltage
8 kV
overvoltage category
III
[Ith] conventional free air thermal current
500 A at <= 104 °F (40 °C)
rated breaking capacity
3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
3600 A <= 104 °F (40 °C) 10 s
2400 A <= 104 °F (40 °C) 30 s
1700 A <= 104 °F (40 °C) 1 min
1200 A <= 104 °F (40 °C) 3 min
1000 A <= 104 °F (40 °C) 10 min
associated fuse rating
400 A aM at <= 440 V
500 A gG at <= 440 V
average impedance
0.26 mOhm at 50 Hz - Ith 500 A
[Ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole
42 W AC-3
65 W AC-1
mounting support
Plate
standards
EN 60947-1
EN 60947-4-1
IEC 60947-1
IEC 60947-4-1
JIS C8201-4-1
product certifications
ABS
BV
CSA
DNV
LROS (Lloyds register of shipping)
RINA
RMRoS
UL
CB
connections - terminals
Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end
Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end
Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end
Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end
Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
Power circuit: lugs-ring terminals 2 cable(s) 0.23 in² (150 mm²)
Power circuit : bolted connection
Power circuit : bar 2 x (30 x 5 mm)
tightening torque
Power circuit: 309.73 lbf.in (35 N.m)
Control circuit: 10.62 lbf.in (1.2 N.m)
control circuit voltage limits
0.85...1.1 Uc at 131 °F (55 °C) operational 40...400 Hz
0.3...0.5 Uc at 131 °F (55 °C) drop-out 40...400 Hz
inrush power in VA
1075 VA at 68 °F (20 °C) (cos ϕ 0.9) 40...400 Hz
hold-in power consumption in VA
15 VA at 68 °F (20 °C) (cos ϕ 0.9) 40...400 Hz
heat dissipation
14 W
operating time
100...170 ms opening
40...65 ms closing
mechanical durability
10 Mcycles
operating rate
2400 cyc/h at <= 131 °F (55 °C)
Environment
IP degree of protection
IP20 front face with shrouds (ordered separately) conforming to IEC 60529
IP20 front face with shrouds (ordered separately) conforming to VDE 0106
protective treatment
TH
ambient air temperature for operation
23...131 °F (-5...55 °C)
ambient air temperature for storage
-76...176 °F (-60...80 °C)
permissible ambient air temperature around the device
-40...158 °F (-40...70 °C)
operating altitude
9842.52 ft (3000 m) without derating
mechanical robustness
Shocks resistance contactor closed 15 Gn for 11 ms
Shocks resistance contactor open 6 Gn for 11 ms
Vibrations resistance contactor closed 5 Gn, 5...300 Hz
Vibrations resistance contactor open 1.5 Gn, 5...300 Hz