-40%

LC1D32M7 Contactor 32 A / 3 poles AC3 / 1NA+1NC, Coil 220Vca NEW IN BOX Original

$ 44.88

Availability: 50 in stock
  • Number of Phases: 3
  • Refund will be given as: Money Back
  • Maximum Amperage: 32 A
  • Brand: Schneider Electric
  • Return shipping will be paid by: Buyer
  • Number of Poles: 3-Pole
  • All returns accepted: Returns Accepted
  • Type: Standard IEC Contactor
  • IEC Utilization Category: AC-3
  • Item must be returned within: 30 Days
  • MPN: LC1D32M7
  • Condition: New
  • Country/Region of Manufacture: France
  • Current Type: AC
  • Mounting Style: DIN Rail Mount
  • Coil Voltage: 220 V
  • Restocking Fee: No

    Description

    LC1D32M7 CONTACTOR 32 AMP COIL 220VAC /  1NO + 1NC
    NEW IN ORIGINAL FACTORY BOX!
    ORIGINAL FROM FRANCE NOT FROM CHINA (Fake Schneider Electric ends with C at the end of the part number: Ex: LC1D32M7
    C
    )
    range
    TeSys
    product name
    TeSys D
    product or component type
    Contactor
    device short name
    LC1D
    contactor application
    Resistive load
    Motor control
    utilisation category
    AC-4
    AC-1
    AC-3
    poles description
    3P
    power pole contact composition
    3 NO
    [Ue] rated operational voltage
    Power circuit <= 690 V AC 25...400 Hz
    Power circuit <= 300 V DC
    [Ie] rated operational current
    32 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
    50 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
    motor power kW
    7.5 kW 220...230 V AC 50/60 Hz AC-3)
    15 kW 380...400 V AC 50/60 Hz AC-3)
    15 kW 415...440 V AC 50/60 Hz AC-3)
    18.5 kW 500 V AC 50/60 Hz AC-3)
    18.5 kW 660...690 V AC 50/60 Hz AC-3)
    7.5 kW 400 V AC 50/60 Hz AC-4)
    motor power HP (UL / CSA)
    2 hp 115 V AC 50/60 Hz 1 phase
    5 hp 230/240 V AC 50/60 Hz 1 phase
    7.5 hp 200/208 V AC 50/60 Hz 3 phase
    10 hp 230/240 V AC 50/60 Hz 3 phase
    20 hp 460/480 V AC 50/60 Hz 3 phase
    30 hp 575/600 V AC 50/60 Hz 3 phase
    control circuit type
    AC 50/60 Hz
    [Uc] control circuit voltage
    220 V AC 50/60 Hz
    auxiliary contact composition
    1 NO + 1 NC
    [Uimp] rated impulse withstand voltage
    6 kV IEC 60947
    overvoltage category
    III
    [Ith] conventional free air thermal current
    10 A 140 °F (60 °C) signalling circuit
    50 A 140 °F (60 °C) power circuit
    Irms rated making capacity
    140 A AC signalling circuit IEC 60947-5-1
    250 A DC signalling circuit IEC 60947-5-1
    550 A 440 V power circuit IEC 60947
    rated breaking capacity
    550 A 440 V power circuit IEC 60947
    [Icw] rated short-time withstand current
    260 A 104 °F (40 °C) - 10 s power circuit
    430 A 104 °F (40 °C) - 1 s power circuit
    60 A 104 °F (40 °C) - 10 min power circuit
    138 A 104 °F (40 °C) - 1 min power circuit
    100 A - 1 s signalling circuit
    120 A - 500 ms signalling circuit
    140 A - 100 ms signalling circuit
    associated fuse rating
    10 A gG signalling circuit IEC 60947-5-1
    63 A gG <= 690 V type 1 power circuit
    63 A gG <= 690 V type 2 power circuit
    average impedance
    2 mOhm - Ith 50 A 50 Hz power circuit
    [Ui] rated insulation voltage
    Power circuit 690 V IEC 60947-4-1
    Power circuit 600 V CSA
    Power circuit 600 V UL
    Signalling circuit 690 V IEC 60947-1
    Signalling circuit 600 V CSA
    Signalling circuit 600 V UL
    electrical durability
    1.65 Mcycles 32 A AC-3 <= 440 V
    1.4 Mcycles 50 A AC-1 <= 440 V
    power dissipation per pole
    2 W AC-3
    5 W AC-1
    safety cover
    With
    mounting support
    Plate
    Rail
    standards
    CSA C22.2 No 14
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508
    product certifications
    DNV
    RINA
    LROS (Lloyds register of shipping)
    CCC
    CSA
    GL
    GOST
    BV
    UL
    connections - terminals
    Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end
    Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end
    Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end
    Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end
    Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end
    Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end
    Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…10 mm²)flexible without cable end
    Power circuit screw clamp terminals 2 0.00…0.02 in² (2.5…10 mm²)flexible without cable end
    Power circuit screw clamp terminals 1 0.00…0.02 in² (1…10 mm²)flexible with cable end
    Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²)flexible with cable end
    Power circuit screw clamp terminals 1 0.00…0.02 in² (1.5…10 mm²)solid without cable end
    Power circuit screw clamp terminals 2 0.00…0.02 in² (2.5…10 mm²)solid without cable end
    tightening torque
    Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
    Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
    Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm
    Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals Philips No 2
    operating time
    12...22 ms closing
    4...19 ms opening
    safety reliability level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    mechanical durability
    15 Mcycles
    maximum operating rate
    3600 cyc/h 140 °F (60 °C)