-40%
ABB A75-30-00 110-120V 60Hz Coil Contactor TESTED
$ 73.39
- Description
- Size Guide
Description
Up for sale is pre-owned fully functional ABB A75-30-00 110-120V 60Hz Coil Contactor.Please review posted photographs to verify hardware specification, cosmetic condition, etc.
<><><> SPECIFICATIONS <><><>
Dimensions:
Width:70 mm | Depth / Length:108 mm | Height:110 mm
Weight:
1.16 kg
<<
Product Net Width:70 mm
Product Net Depth / Length:108 mm
Product Net Height:110 mm
Product Net Weight:1.16 kg
<<
Number of Main Contacts NO:3
Number of Main Contacts NC:0
Number of Auxiliary Contacts NO:0
Number of Auxiliary Contacts NC:0
Standards:
Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1
Rated Operational Voltage:
Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 125 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 125
(690 V) 55 °C 105
(690 V) 70 °C 85
Rated Operational Current AC-3 (Ie):
(415 V) 55 °C 72 A
(440 V) 55 °C 70 A
(500 V) 55 °C 65 A
(690 V) 55 °C 46 A
(1000 V) 55 °C 28 A
(380 / 400 V) 55 °C 75 A
(220 / 230 / 240 V) 55 °C 75
Rated Operational Power AC-3 (Pe):
(415 V) 40 kW
(440 V) 40 kW
(500 V) 45 kW
(690 V) 40 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
Rated Operational Power AC-6b (Pe):
(230 / 240 V) 40 °C, 50 / 60 Hz 28 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 28 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 24.5 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 48 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 41 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 48 kvar
(440 V) 40 °C, 50 / 60 Hz 52 kvar
(440 V) 55 °C, 50 / 60 Hz 52 kvar
(440 V) 70 °C, 50 / 60 Hz 45 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 60 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 60 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 51 kvar
(690 V) 40 °C, 50 / 60 Hz 82 kvar
(690 V) 55 °C, 50 / 60 Hz 82 kvar
(690 V) 70 °C, 50 / 60 Hz 70 kvar
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
10 x Ie AC-3
Short-Circuit Protective Devices:
gG Type Fuses 160 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 600 cycles per hour
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 110 V / 60 Hz 110 ... 120 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 18 V·A
Average Pull-in Value 50 Hz
190 V·A
Average Pull-in Value 60 Hz
180 V·A
Operate Time
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing:
8 ... 27 ms
Connecting Capacity Main Circuit:Flexible with Cable End: 6 ... 16 mm²
Rigid Cable: 6 ... 25 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Connecting Terminals (delivered in open position) Main Poles:
M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
Terminal Type:
Screw Terminals
<
Ambient Air Temperature:Close to Contactor Fitted with Thermal O/L Relay: -25 ... +55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc): -40 ... +55 °C
Close to Contactor without Thermal O/L Relay (Uc): -40 ... +70 °C
Close to Contactor for Storage :-60 ... +80 °C
Climatic Withstand:
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible:
3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: B1 10 K40
Open, Shock Direction: B1 5 K40
Shock Direction: A 20 K40
Shock Direction: B2 15 K40
Shock Direction: C1 20 K40
Shock Direction: C2 20 K40
RoHS Status:
Following EU Directive 2011/65/EU
BV Certificate:
BV_2634H07559E0
CB Certificate:
CB_CN45324
CCC Certificate:
CCC_2018010304129267 CCC_2008010309289461
CQC Certificate:
CQC2018010304129267 CQC2008010309289461
CSA Certificate:
CSA_1033838_LR056745
Declaration of Conformity - CCC:
2020980304001622 2020980304001226
Declaration of Conformity - CE:
1SBD250801U1000
DNV Certificate:
DNV-GL_TAE00000TX
DNV GL Certificate:
DNV-GL_TAE00000TX
EAC Certificate:
EAC_RU C-FR ME77 B03599
Environmental Information:
1SBD250010E1003
Instructions and Manuals:
FPTC407700P0003
LR Certificate:
LRS_9830011E4
RINA Certificate:
RINA_ELE172319XG001
RMRS Certificate:
RMRS_0507015250
RoHS Information:1
SBD250801U1000
UL Certificate:
UL_20120830-E312527-10-1
UL Listing Card:
UL_E312527
<
Object Classification Code:
Q
ETIM 4:
EC000066 - Magnet contactor, AC-switching
ETIM 5:
EC000066 - Magnet contactor, AC-switching
ETIM 6:
EC000066 - Power contactor, AC switching
ETIM 7:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
E-Number (Finland):
3709148